TCM 1 1767-(R) – Blanc Aero Industries – LISI – La Glèbe, La Rouquette, (FR) PQ426

QAR: Click Here
Conditions for approval required by:  Julien Gauther

4 Replies to “TCM 1 1767-(R) – Blanc Aero Industries – LISI – La Glèbe, La Rouquette, (FR) PQ426”

  1. Thread major diameter (dimension 21 on dimensional test report):
    As per EN2874, thread major diameter d max = D1min -0,025
    D1min = 12 – 0,034 = 11,966, so, dmax = 11,966 – 0,025 = 11,941 mm
    Hopefully, actual values are compliant to dmax = 11,941 mm.
    Could you please consider this for next productions?

    Salt spray test: 5 bolts were tested. As per ISO9154, clause 5.3.7, 100% of mfg batch should have undergone salt spray test for Acceptance. However, I do agree with LISI and Keith that a manufacturer cannot sell parts, which have seen salt spray fog. So, I agree with 5 bolts tested (sample size required for Qualification).

    Which type of passivation has been carried out?

    Many thanks in advance
    Best regards, Julien

  2. Thank you for the comments Julien.
    Nicolas, please review and correct the dimension requirement for the thread major diameter and check that your measurements for this are compliant.
    We note that it is not possible to carry out 100% salt spray as it is a destructive test.
    Please state the passivation method used for these parts.
    Thanks, Keith

    1. Hello everyone,

      Attached you will find the updated dimensional report with the corrected requirement for dimension 21.

      Regarding passivation, we have produced type C7 referenced in EN2516.
      Thank you.

      Best regards,
      Nicolas Arlabosse

  3. Hi Keith, Hi Nicolas,

    Many thanks for all your answers, I am happy with them.
    Approved from my side.
    Have a nice day
    Best regards, Julien,

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.