TCM 1 1701-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ626

QAR: Click Here
Conditions for approval required by:  Julien Gauther

One Reply to “TCM 1 1701-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ626”

  1. MPI was carried out on 50 nuts, which is a good practice since ISO5858 does not require any NDT for Acceptance.
    Something to point out:
    Mfg batch size is 822 parts.
    If we had NDT as specified in EN4048 for instance, we would have 200 parts MP inspected (AQL = 0,065% for surface discontinuities, see EN4048:2006, tables 3 and 4).
    Anyway, no NDT required for Acceptance, just for information.
    Approved from my side.
    Best regards
    Julien

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.