TCM 2 1594-(R) – Décomatic – Ste Maure de Touraine (FR) PQ520

QAR: Click Here
Conditions for approval required by:  Philip Edwards

2 Replies to “TCM 2 1594-(R) – Décomatic – Ste Maure de Touraine (FR) PQ520”

  1. please confirm where the non conformance was found (in house or by customer). do Decomatic understand why there was a non conformance. was this found during sampling and then then whole batch was examined.

  2. the non conformance was detected at Gillis during the dye penetrant inspection before silver plating .
    I have asked to a visual inspection of the full batch by DECOMATIC when the batch has been returned by GILLIS to DECOMATIC . There is no other defect in the batch ( see visual report included in “additionnal document”)
    A root cause analysis is underway at DECOMATIC and should be achieved in the beginning of next week .