  1. – The EN4234 has L, M and N style, but no mention of in production checks for N style.
    – Do we have all the applicable routes? appear to be missing
    K07 0006 for Hopinox 12 ou EN4234 L (sup au100-120) (presume this means for other sizes than 100-120 as K07 0005 quotes 100-120 too)
    K18 0001 for Hopinox 5M ou EN4234N (presume this is for the N style)
    – None of the routes call out the passivation sub-contractor. We need to see list of approved subcontractors for this operation that Caillau use and their relevant NADCAP and ISO accreditations.

  2. Comments now addressed
    – Control document added for N style
    – Missing routes added
    – Passivation sub-contractor named and certificates provided