TCM 1 905-(R) – Amphenol Socapex – Thyez (FR) PQ337

QAR: Click Here
Conditions for approval required by:  Edward Ndegwa

3 Replies to “TCM 1 905-(R) – Amphenol Socapex – Thyez (FR) PQ337”

  1. Page 21 of 70 Note made that extinguishing fluid is banned in France. ? Does this mean exposure to alternate extinguish fluid not performed at all? I only found data on Halon being banned but there are new replacements.

    Measurement report page 106, 107 and 108 – micro cut occurrence observed. Why is this deviation only on one contact repeatably.

  2. Pierre BAENA-> No extinguishing fluid has been performed as fluid is not procurable and not alternative fluid is officially approved yet. ASD STAN needs to introduce and define new replacements

    Pierre BAENA-> During sinusoidal vibration test it has observed micro cuts only on second (Z) axis one of the three axes and they are accepted based on :
    -There is no evidence of damage or pollution of the centre contacts or of the insert of connector A1 (nota: No discontinuity recorded on quadrax inserted on connector B1).
    -No discontinuity observed neither on the other axes (including the 3rd and last (Y)) nor during the shock test, nor during the following tests. Therefore test was accepted.