TCM 1 1738-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ588

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 1738-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ588”

  1. There is a mistake in EN3712:2007:
    In EN3712:2007, rivet hole dimension “S” has a tolerance equal to 0/+2,2 mm.
    Fortunately, HFS considered actual tolerance: 0/+0,2 mm.
    Thus, this is not a blocking point, many thanks to HFS for correcting this.
    This should be addressed to ASD-STAN for correction.

    QTR, dimensional test report:
    “J” dimension is considered as minimum value whereas EN3712 specifies this dimension as a maximum.
    Hopefully, actual values are in line with 8,7 mm maximum.
    Could you please fix this?
    Many thanks in advance
    Best regards, Julien

  2. Dear Mrs. Richards, Mrs. Lacombe,
    Many thanks for updating QTR7580.
    I am happy with this, so, approved from my side
    Best regards, Julien

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.