QAR: Click Here
Conditions for approval required by: Julien Gauther

Certification of Aerospace Products to international quality Standards
Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.
Salt spray test: as per EN2583, clause 5.3.7, salt spray test shall be carried out on 100% of the parts. In CoC, 5 parts underwent this test. Even though actual sample size is not in line with EN2583, I do agree with this one since, from my point of view, this test can be seen as a destructive one. Thus, I assume that selected sample size is compliant to EN2583, table 8, column B.
EN2583 should be updated in that way: Moreover, in EN2583 table 2, salt spray test is classified in the destructive category. This is just something to point out.
FPI: is it possible to get fluorescent penetrant inspection report? Indeed, EN2583, clause 5.5.5, requires this test for Acceptance, sample size and NQA are specified in EN2583, tables 3 and 4.
Hopefully, we do have micrographic examinations on 5 bolts to check the presence or not of cracks.
Many thanks in advance
Best regards
Juilen
Just a small clarification:
Salt spray test: as per EN2583, clause 5.3.7, salt spray test shall be carried out on 100% of the parts for Acceptance. For qualification only 5 pa
Just a small clarification:
Salt spray test: as per EN2583, clause 5.3.7, salt spray test shall be carried out on 100% of the parts for Acceptance. For qualification only 5 parts shall be salt spray tested.
All is clear for me now.
Many thanks to Matt, Robert and Marko.
Approved from my side.
Have a nice day
Best regards
Julien