TCM 1 1595-(R) – Caillau – Romorantin Lanthenay (FR) PQ154

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 1595-(R) – Caillau – Romorantin Lanthenay (FR) PQ154”

  1. Passivation: parts have been passivated against AMS2700 instead of EN2516. Could you please clarify?
    EN3077: 2022 is the lastest issue. On ASD-CERT webiste, it is mentioned prEN3077:1998. Which issue has been applied?
    Shall we have relevant sample sizes for Acceptance test as per EN3077, table 3?
    Many thanks in advance
    Best regards
    Julien

  2. Passivation : There has been discussion both with ASD CERT and the manufacturer and it has been agreed that the AMS standard can be used. The discussion is provided in a MS Word document in the Qualification Report section of this renewal report.
    Regarding EN 3077, the manufacturer confirmed they had integrated the 2022 version in their quality system. There was no impact on production and qualification conditions.
    Regarding the acceptance tests, the manufacturer stated that you can see these tests in tests E (destruction torque), F (tightening range) and G (re-use test) in control plans M 81 1000 and M 80 1002, 7 and 8 in control plan Q 26 0006 and 4,7,8, in control plan M 18 1000. These documents are in French because they are used by French operators, but they have been uploaded to the Qualification Report section of this renewal report.

  3. Hello Keith,
    Many thanks for updating QTR section wtih all these data.
    I am happy with all answers from you and Laurent Uzac (PPAP/FAI Coordinator at Caillau facilities), so, approved from my side.
    Best regards
    Julien

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.