TCM 1 1294-3 – (R) – Blanc Aero Industries – LISI – La Glèbe, La Rouquette, (FR) PQ235 EN3008

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 1294-3 – (R) – Blanc Aero Industries – LISI – La Glèbe, La Rouquette, (FR) PQ235 EN3008”

  1. Salt spray test: as per EN2583, salt spray test shall be carried out on 100% of mfg batch for Acceptance.
    In test report, 5 parts has been salt spray tested during 5 hours.
    From my point of view, I am not really sure that 100% of a mfg batch shall undergo a salt spray test.
    Salt spray test may be considered as a destructive test even if 2h duration is short for this kind of test and grade (Inconel 718 is really high corrosion resistant).
    5 samples for this test is in line with EN2583, table 8, column B (destructive test).
    In addition, as per EN2583, table 2, salt spray test is classified in destructive tests category.
    What is LISI’s and Keith’s points of view?

    Process Flow Chart: why is it written P2 revision for EN2583? Actual revision is EN2583:2019.
    Many thanks in advance,
    Best regards,
    Julien

    1. Julien, thank you for your review and your comments. At ASD CERT, we have seen the issue with 100% batch testing of passivation with salt spray and we know this is incorrect as consider it a destructive test so we should ask ASD STAN to correct EN2583. In the meantime, we can accept the acceptance test carried out by Lisi on the 5 parts. The flow chart should reference the 2019 version of EN2583 so I will ask Lisi to update the flowchart and I will seal it again.

  2. Many thanks Keith for reminding me that this topic is ongoing at ASD-CERT.
    All is clear for me now (including PFC update in progress).
    Thus, approved from my side.
    Best regards,
    Julien

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.