QAR: Click Here
Conditions for approval required by: Julien Gauther

Certification of Aerospace Products to international quality Standards
Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.
EN3614-060:
Tensile load requirement as per EN2576 is 19578 N. In QTR, actual requirement is 19576 N. We have only a difference of 2 N which is negligible. So, just something to point out, not blocking from my side.
PFC: EN3614 issue written down is March 2020. The latest issue of EN31614 is 2009 (March 2010 for NF EN 3614).
EN3614-060:
PFC: EN3614 issue written down is March 2020. The latest issue of EN31614 is 2009 (March 2010 for NF EN 3614).
Many thanks in advance
Best regards, Julien
Q : EN3614-060:
Tensile load requirement as per EN2576 is 19578 N. In QTR, actual requirement is 19576 N. We have only a difference of 2 N which is negligible. So, just something to point out, not blocking from my side.
A : typing error . Tensile values are well above the specifications :
Q PFC: EN3614 issue written down is March 2020. The latest issue of EN31614 is 2009 (March 2010 for NF EN 3614).
EN3614-060:
PFC: EN3614 issue written down is March 2020. The latest issue of EN31614 is 2009 (March 2010 for NF EN 3614).
A; manufacturing route have been updated in the QTR and in the Manufacturing route boxS
All is clear for me Daniel, many thanks!
Approved from my side.
Best regards, Julien