TCM 2 1633-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ543

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 2 1633-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ543”

  1. QTR, dimensions test report:
    Are rivet holes dimpled or countersunk?
    The tolerance is different depending on the option selected by manufacturer.
    We do have tolerance for “S” dimension: either +0,2/-0 or +0,4/-0.
    Coudl you please clarify?
    I agree with all Kees’ comments in “Particular remarks” section.
    Many thanks in advance
    Best regards
    Julien

  2. Hi Julien.

    Below is the clarification as requested by you.
    • The rivet holes are dimpled.
    • The QTR 7624 has been updated and is now QTR7624A. The adjustment has been made in the “Dimensions table” (page 3 of 3) in line with the “Marker” S. The tolerance -0/+0,2 is now indicated in the column with “required dimensions”. The “Measured dimensions” column shows that the measured values fall within the tolerance limits.

    Best regards
    Kees

  3. Hi Kees,
    Many thanks for this update.
    Approved from my side.
    Have a nice day
    Best regards Julien