QAR: Click Here
Conditions for approval required by: Julien Gauther

Certification of Aerospace Products to international quality Standards
Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.
In the original Test Report (mfg batch 506102, in 2007), we have 3 bolts tested for both tensile and double shear tests.
In the new edition of Test Report (same batch 506102, edition of May 2021), 5 bolts have been tested this time, so, 2 more than the previous one.
ISO7689 (edition 1988 and edition 2008) requires 3 bolts to be both tensile and double shear tested when the manufacturing batch size is lower or equal to 500 parts.
Thus, even if this difference is a bit strange, both reports are compliant.
Note : as stated in the new edition of the test report, fatigue test is not required if we consider ISO7689:2008.
Back in the days, fatigue test was applicable (ISO7689:1988) and this is why we have fatigue test results.
Approved on my side.
Best regards.