TCM 1 1709-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ630

QAR: Click Here
Conditions for approval required by:  Julien Gauther

4 Replies to “TCM 1 1709-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ630”

  1. Some sample sizes are different between QTS and Test Report. Sample sizes in Test Report are in line with relevant manufacturing batch size whereas those mentioned in QTS are not.
    Could you please fix this?
    Many thanks in advance
    Best regards
    Julien

    NOTE: always good to see that MPI was carried out on this batch even though ISO5858 tech. spec. does not specify any NDT for Acceptance (only for Qualification).

  2. Hi Julien,

    Thanks for your response. The QTS has been amended and added to the QAR.

    Any issues, please let me know.

    Thanks

    Marko

    1. It was a mistake , we take into account the qualification requirements and not the acceptance requirements for the sampling ? Please see the QTS enclosed (In additonal documents) updated.

      Regards,

      Nadège on Behalf of Geneviève Lacombe

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.