TCM 1 1207-LISI Aerospace [Bestas FTB] Gaziemir (TR) EN3614-050, -060

QAR: Click Here
Conditions for approval required by:  Julien Gauther

5 Replies to “TCM 1 1207-LISI Aerospace [Bestas FTB] Gaziemir (TR) EN3614-050, -060”

  1. EN3614-050-036 (automatic forging):
    FPI: 2 bolts were rejected due to the presence of laps underhead. Did you carry out microscopic examinations on them to determine the root cause? Hopefully, due to mfg batch size, the entire batch has been FP inspected. However, for a bigger batch quantity, sample quantity would be 200 for instance.
    The idea is to make sure that, for future batches, forging operations (I assume that this type of defect comes from head forging) will not generate this kind of defect.
    Many thanks in advance
    Best regards
    Julien

    1. Hello Julien,

      Yes, if FPI find any discontinuous on part they bring the all suspecting parts in the laboratory and they cut the part and carry out microscopic examinations.
      Best regards
      Buse.

  2. Hi Buse and thank you for your response. Can you also please confirm, as requested by Julien, that the entire batch was FP inspected? Was a root cause determined for the underhead laps?

    1. Hello Keith and Julien,

      All parts have been 100% FPI. You can see that FPI has been done to the entire lot on the FPI process sheet. It is caused by the underhead lap, forging or raw material.
      Best regards
      Buse.

  3. Many thanks to you, Buse and Keith.
    All is clear for me now. 100% FP inspection and root cause analysis ahve been carried out.
    So, approved from my side.
    Have a nice day
    Best regards
    Julien