TCM 1 1605-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ541

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 1605-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ541”

  1. Shall we have cadmium thickness values (on threaded area and all surfaces which can be contacted by a 20 mm diameter ball only, as specified in EN3753)?
    Many thanks in advance
    Best regards
    Julien

  2. Julien
    The original SD-TR-15370077-Rev 3, EN3733-060 on which the sample size was stated but not the thickness and which has now been replaced by SD-TR-15370077-Rev 4, EN3733-060.
    There is currently an IT issue on the test report it is the reason why the value and the sampling are written in the case notes.
    Sample size (Ech.) is 20. Minimum cadmium thickness is 6.27 and maximum thickness is 7.92.

    I hope this has provided clarity in response to your comment.

    Regards
    Kees

  3. Hi Kees,
    Many thanks for your detailed answer, dully noted!
    All is clear now, thanks to HFS team as well.
    Approved from my side.
    Best regards
    Julien

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.