Thread major diameter “d max.” shall be equal to D1 min. ? 0,025.
In FAIR, “d max“ equals to 12,000 mm instead of D1min – 0,025 = 12,000 – 0,034 – 0,025 = 11,941.
Actual values are in line with this maximum tolerance. However, could you please consider it next time?
Shall we have fluorescent penetrant inspection report please?
Many thanks in advance
Best regards
Julien
Many thanks to Buse and Marko for answering and updating FAIR including now:
– right max major diameter tolerance,
– Fluorescent Penetrant Inspection report.
All is fine for me now, so, approved from my side.
Have a nice day
Best regards Julien