TCM 2 1607-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ513

QAR: Click Here
Conditions for approval required by:  Julien Gauther

One Reply to “TCM 2 1607-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ513”

  1. 125 nuts were magnetic particle inspected, which is a very good practice since ISO5858 does not require any non-destructive test for Acceptance. Just something to point out, but not blocking.
    Hardness test results are available in “Métallurgie” section, but not in “Hardness” section, just something to mention, not blocking.
    Locking torque test was carried out on 15 cycles, which is more stringent than required for Acceptance (single-cycle test).
    Finally, no blocking point, so, approved from my side.
    Best regards
    Julien

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.