QAR: Click Here
Conditions for approval required by: Edward Ndegwa

Certification of Aerospace Products to international quality Standards
Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.
Similar to Andres comment. I have observed that there is a mistake with the test proposed
EN3646-001 requests to perform test EN2591-303 (refer to table 16)
QTP requests to perform test EN2591-305
Please can you clarify
Hello Edward,
thanks for your message.
Indeed, there is a discrepance between EN3646-001 and TE QTP for the renewal:
– EN3646-001 table 16 for maintenance of qualification ask to perform test EN2591-303
– TE QTP for maintenance of qualifciation ask to perform test EN2591-305
The discrepancy can be justified as follows:
– EN3646-001 shows test EN2591-303 as “Not applicable” in the list of tests
– Further test EN2591-303 is asking to perfrom “Insulation resistance test” at the end, but no resistance value is defined in EN3646-001 (like it is done in EN3645 or EN2997).
– we have group consensus at ASD-STAN to replace EN2591-303 by EN2591-305 in next revision of EN3646-001
– this new rule to perform test EN2591-305 was already applied during renewal of PQ157 for connectors EN3646 from Souriau and was agreed before in related Souriau QTP JQP2021-001-AM.
Hope it explains the deviation and is acceptable for you.
Best regards
Steffen Ohde