TCM 1 1290-(R) – TE Deutsch, Bengaluru – (IN) PQ292

QAR: Click Here
Conditions for approval required by:  Andre LEPERS

2 Replies to “TCM 1 1290-(R) – TE Deutsch, Bengaluru – (IN) PQ292”

  1. Hello,
    I have identified a deviation and I would like to have clarification.
    EN3646-001 requests to perform test EN2591-303 (refer to table 16)
    QTP requests to perform test EN2591-305.
    Thank you for your answer.
    Best regards
    André

  2. Hello André,

    thanks for your message.
    Indeed, there is a discrepance between EN3646-001 and TE QTP for the renewal:
    – EN3646-001 table 16 for maintenance of qualification ask to perform test EN2591-303
    – TE QTP for maintenance of qualifciation ask to perform test EN2591-305

    The discrepancy can be justified as follows:
    – EN3646-001 shows test EN2591-303 as “Not applicable” in the list of tests
    – Further test EN2591-303 is asking to perfrom “Insulation resistance test” at the end, but no resistance value is defined in EN3646-001 (like it is done in EN3645 or EN2997).
    – we have group consensus at ASD-STAN to replace EN2591-303 by EN2591-305 in next revision of EN3646-001
    – this new rule to perform test EN2591-305 was already applied during renewal of PQ157 for connectors EN3646 from Souriau and was agreed before in related Souriau QTP JQP2021-001-AM.
    Hope it explains the deviation and is acceptable for you.
    Best regards
    Steffen Ohde