QAR: Click Here
Conditions for approval required by: Julien Gauther

Certification of Aerospace Products to international quality Standards
Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.
Dear all,
“Substantiation by analogy” section states that we do have a test report available for EN3052-060 in “additional document” section.
Apparently, EN3052-060 test report may not have been uploaded.
Many thanks in advance
Best regards
Julien
Dear all,
I received QTR for EN3052 diameter 6, many thanks for that.
Some remarks about this one:
Clause 3.4.4, tensile test: could you please replace 2390 MPa by 23,9 kN?
Actual values shall be corrected in the same way.
Test report N°A837880 is correct.
Many thanks in advance
Best regards
Julien
done
All is fine for me now.
Many thanks to Daniel and AHG’s team.
Approved from my side.
Best regards
Julien