QAR: Click Here
Conditions for approval required by: Philip Edwards
Certification of Aerospace Products to international quality Standards
Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.
NADCAP Cert for NDT out of date
Silver plating check 3 samples need to be tested only 1 seems to have been done.
Hardness is in HV, spec requires HRC are these values ok
Good Morning Phil,
Sorry for the late answers.
– NADCAP & EN9100 certificate have been updated and will be provided to Antoine DIAZ.
– Silver plating check, as per Aeroprotec certificate sampling plan follows their internal specification IQ6-0-0, for less than 501 parts, 5 parts are inspected.
– On our test report only Vickers measurements appeared, now the conversion to HRC is mentioned. 304/333HV –> 31.2/34.7 HRC, compliant to EN2576 (26/35HRC).
All updated documentation will be provided to Antoine DIAZ.
Have a nice day.
Best regards,
Quentin