TCM 1 698-(R) – Blanc Aero Industries – LISI – Villefranche de Rouergue (FR) PQ146

QAR: Click Here
Conditions for approval required by:  Julien Gauther

_________________________

One Reply to “TCM 1 698-(R) – Blanc Aero Industries – LISI – Villefranche de Rouergue (FR) PQ146”

  1. PQ146-certificate-of-conformity
    page 2/6
    As per EN3752, table 4, discontinuities are considered as major defect with AQL = 0,065%. So, sampling shall be 200 parts instead of 80 (mfg batch size is 502 parts). The down arrow in table 4 is applicable for Acceptance/Rejection criteria and related sampling as well.
    It should be good to add sampling size for dimensional, marking, surface treatment controls.
    Page 5/6:
    200 parts inspected should have been enough since we have up arrow in EN3752, table 4. But 315 is better.
    It should be good to add sampling size for dimensional, marking, surface treatment controls.
    Thank you.
    Kind regards.

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.